[Products]

Flat Rack Plug-&-Play Containerized Genset

Fast and flexible power anywhere.

A fully factory-assembled 500 kW gas genset designed for rapid deployment and easy relocation – even in remote and demanding environments.
The whole plant ships on a standard flat rack: everything is mounted, wired and tested before it leaves Mendig, so commissioning on site is connections and a start-up rather than a build.

[About]

Technical Specifications

Electrical output

500 kW

Format

Flat rack

Install

Plug & play

Key Benefits

Fully factory-assembled and pre-tested

Rapid deployment, minimal site work

Built for remote and demanding environments

Relocatable – the plant can follow the load

[Options]

Generator Type

Configuration Solution type Fuel type Grid frequency Electrical power / kW Electrical efficiency / % Thermal power / kW Overall efficiency / %
M06 GEN P115 GEN LPG / Propane 50 Hz 115 30.7 – –
M06 GEN H122 GEN Woodgas 50 Hz 122 34.8 – –
M06 GEN G140 GEN Natural Gas 50 Hz 140 38.6 – –
M06 GEN B140 GEN Biogas 50 Hz 140 39.3 – –
M08 GEN H166 GEN Woodgas 50 Hz 166 34.9 – –
M06 GEN P173 GEN LPG / Propane 50 Hz 173 34.9 – –
M06 GEN G200 GEN Natural Gas 50 Hz 200 41.0 – –
M06 GEN B200 GEN Biogas 50 Hz 200 41.8 – –
M06 GEN P205 GEN LPG / Propane 50 Hz 205 35.8 – –
M08 GEN P233 GEN LPG / Propane 50 Hz 233 35.0 – –
M06 GEN G250 GEN Natural Gas 50 Hz 250 41.8 – –
M06 GEN B250 GEN Biogas 50 Hz 250 42.6 – –
M12 GEN H250 GEN Woodgas 50 Hz 250 35.0 – –
M08 GEN G260 GEN Natural Gas 50 Hz 260 41.0 – –
M08 GEN B260 GEN Biogas 50 Hz 260 41.7 – –
M08 GEN P260 GEN LPG / Propane 50 Hz 260 35.9 – –
M08 GEN G333 GEN Natural Gas 50 Hz 333 41.9 – –
M08 GEN B333 GEN Biogas 50 Hz 333 42.6 – –
M12 GEN P350 GEN LPG / Propane 50 Hz 350 35.1 – –
M12 GEN G400 GEN Natural Gas 50 Hz 400 41.1 – –
M12 GEN B400 GEN Biogas 50 Hz 400 41.9 – –
M12 GEN P450 GEN LPG / Propane 50 Hz 450 36.0 – –
M12 GEN G500 GEN Natural Gas 50 Hz 500 42.1 – –
M12 GEN B500 GEN Biogas 50 Hz 500 42.7 – –
GEN P130/60 Hz GEN LPG / Propane 60 Hz 130 31.0 – –
GEN H140/60 Hz GEN Woodgas 60 Hz 140 33.3 – –
GEN G150/60 Hz GEN Natural Gas 60 Hz 150 37.0 – –
GEN B150/60 Hz GEN Biogas 60 Hz 150 37.8 – –
GEN P173/60 Hz GEN LPG / Propane 60 Hz 173 33.5 – –
GEN H180/60 Hz GEN Woodgas 60 Hz 180 33.4 – –
GEN P205/60 Hz GEN LPG / Propane 60 Hz 205 34.3 – –
GEN G210/60 Hz GEN Natural Gas 60 Hz 210 39.5 – –
GEN B210/60 Hz GEN Biogas 60 Hz 210 40.2 – –
GEN P233/60 Hz GEN LPG / Propane 60 Hz 233 33.5 – –
GEN G250/60 Hz GEN Natural Gas 60 Hz 250 40.3 – –
GEN B250/60 Hz GEN Biogas 60 Hz 250 41.1 – –
GEN P260/60 Hz GEN LPG / Propane 60 Hz 260 34.3 – –
GEN H275/60 Hz GEN Woodgas 60 Hz 275 33.5 – –
GEN G280/60 Hz GEN Natural Gas 60 Hz 280 39.5 – –
GEN B280/60 Hz GEN Biogas 60 Hz 280 40.2 – –
GEN G333/60 Hz GEN Natural Gas 60 Hz 333 40.4 – –
GEN B333/60 Hz GEN Biogas 60 Hz 333 41.2 – –
GEN P350/60 Hz GEN LPG / Propane 60 Hz 350 33.6 – –
GEN G420/60 Hz GEN Natural Gas 60 Hz 420 39.6 – –
GEN B420/60 Hz GEN Biogas 60 Hz 420 40.4 – –
GEN P450/60 Hz GEN LPG / Propane 60 Hz 450 34.5 – –
GEN G500/60 Hz GEN Natural Gas 60 Hz 500 40.5 – –
GEN B500/60 Hz GEN Biogas 60 Hz 500 41.2 – –
M06 GEN+ P115 GEN+ LPG / Propane 50 Hz 115 30.7 148 70.2
M06 GEN+ H122 GEN+ Woodgas 50 Hz 122 34.8 102 63.9
M06 GEN+ G140 GEN+ Natural Gas 50 Hz 140 38.6 111 69.2
M06 GEN+ B140 GEN+ Biogas 50 Hz 140 39.3 98 66.8
M08 GEN+ H166 GEN+ Woodgas 50 Hz 166 34.9 140 64.3
M06 GEN+ P173 GEN+ LPG / Propane 50 Hz 173 34.9 171 69.4
M06 GEN+ G200 GEN+ Natural Gas 50 Hz 200 41.0 131 67.8
M06 GEN+ B200 GEN+ Biogas 50 Hz 200 41.8 120 66.9
M06 GEN+ P205 GEN+ LPG / Propane 50 Hz 205 35.8 174 66.2
M08 GEN+ P233 GEN+ LPG / Propane 50 Hz 233 35.0 233 70.0
M06 GEN+ G250 GEN+ Natural Gas 50 Hz 250 41.8 128 63.2
M06 GEN+ B250 GEN+ Biogas 50 Hz 250 42.6 120 63.0
M12 GEN+ H250 GEN+ Woodgas 50 Hz 250 35.0 208 64.1
M08 GEN+ G260 GEN+ Natural Gas 50 Hz 260 41.0 173 68.3
M08 GEN+ B260 GEN+ Biogas 50 Hz 260 41.7 159 67.2
M08 GEN+ P260 GEN+ LPG / Propane 50 Hz 260 35.9 224 66.8
M08 GEN+ G333 GEN+ Natural Gas 50 Hz 333 41.9 174 63.8
M08 GEN+ B333 GEN+ Biogas 50 Hz 333 42.6 162 63.3
M12 GEN+ P350 GEN+ LPG / Propane 50 Hz 350 35.1 348 70.0
M12 GEN+ G400 GEN+ Natural Gas 50 Hz 400 41.1 264 68.2
M12 GEN+ B400 GEN+ Biogas 50 Hz 400 41.9 241 67.1
M12 GEN+ P450 GEN+ LPG / Propane 50 Hz 450 36.0 376 66.1
M12 GEN+ G500 GEN+ Natural Gas 50 Hz 500 42.1 255 63.6
M12 GEN+ B500 GEN+ Biogas 50 Hz 500 42.7 241 63.3
GEN+ P130/60 Hz GEN+ LPG / Propane 60 Hz 130 31.0 161 69.4
GEN+ H140/60 Hz GEN+ Woodgas 60 Hz 140 33.3 125 63.0
GEN+ G150/60 Hz GEN+ Natural Gas 60 Hz 150 37.0 127 68.4
GEN+ B150/60 Hz GEN+ Biogas 60 Hz 150 37.8 112 66.0
GEN+ P173/60 Hz GEN+ LPG / Propane 60 Hz 173 33.5 184 69.1
GEN+ H180/60 Hz GEN+ Woodgas 60 Hz 180 33.4 160 63.1
GEN+ P205/60 Hz GEN+ LPG / Propane 60 Hz 205 34.3 189 65.9
GEN+ G210/60 Hz GEN+ Natural Gas 60 Hz 210 39.5 149 67.5
GEN+ B210/60 Hz GEN+ Biogas 60 Hz 210 40.2 134 65.9
GEN+ P233/60 Hz GEN+ LPG / Propane 60 Hz 233 33.5 248 69.1
GEN+ G250/60 Hz GEN+ Natural Gas 60 Hz 250 40.3 145 63.7
GEN+ B250/60 Hz GEN+ Biogas 60 Hz 250 41.1 130 62.5
GEN+ P260/60 Hz GEN+ LPG / Propane 60 Hz 260 34.3 241 66.1
GEN+ H275/60 Hz GEN+ Woodgas 60 Hz 275 33.5 249 63.8
GEN+ G280/60 Hz GEN+ Natural Gas 60 Hz 280 39.5 200 67.7
GEN+ B280/60 Hz GEN+ Biogas 60 Hz 280 40.2 180 66.1
GEN+ G333/60 Hz GEN+ Natural Gas 60 Hz 333 40.4 194 63.9
GEN+ B333/60 Hz GEN+ Biogas 60 Hz 333 41.2 175 62.8
GEN+ P350/60 Hz GEN+ LPG / Propane 60 Hz 350 33.6 374 69.5
GEN+ G420/60 Hz GEN+ Natural Gas 60 Hz 420 39.6 300 67.9
GEN+ B420/60 Hz GEN+ Biogas 60 Hz 420 40.4 270 66.4
GEN+ P450/60 Hz GEN+ LPG / Propane 60 Hz 450 34.5 407 65.7
GEN+ G500/60 Hz GEN+ Natural Gas 60 Hz 500 40.5 285 63.6
GEN+ B500/60 Hz GEN+ Biogas 60 Hz 500 41.2 258 62.5

Do You Need
a Consultation?

Fill out the form, and our specialist will contact you and answer all your questions.

e.g. type of fuel, required power, project location, planned operating hours per year

Your details are used only to process your request. By submitting this form, you confirm that you have read and agree to our Privacy Policy.

Find your ENERGIN®

Step 1 of 5

Which fuel will you run on?

Determines the engine series and gas train.

Prefer to write to us directly? Contact us